FlexPAK High-Vacuum Unit
Use
Nederman FlexPAK is a demand-controlled high-vacuum unit for dust, fumes and metal chips.
- Application
- Welding and cutting fumes · Grinding dust
- System Type
- Central system
- Maximum Airflow
- 1300 m³/h
- Motor Power / Supply
- 18.5 kW / 400 V; 21.5 kW / 460 V
- Filter Area
- 6 m²
- Inlet / Outlet Diameter
- 150 / 160 mm
A Closer Look At The Product
FlexPAK High-Vacuum Unit Operation And Installation
Operating arrangements account for changing airflow demand across multiple connection points. Extraction pipes, collection vessel and control connections are sized together.
Features
- Vacuum controlAdjusts suction to demand to manage energy use.
- Automatic cleaningSupports filter life and reduces maintenance needs.
- PLC controlsAllow the system to be monitored and adjusted.
- OperationControls help manage performance and maintenance needs.
- Safety connectionsSupport for fire alarms and container-level sensors.
- InstallationSupplied as a ready-to-use unit.
FlexPAK DX: Versions For Combustible Dust
FlexPAK DX is designed for extraction in specified combustible-dust applications covered by ATEX requirements.
- FlexPAK DXEquipped with an explosion-relief panel to vent explosion pressure and flame.
- FlexPAK DX F2A flameless venting option for specified indoor installations.
Where Is It Used?
Let’s assess it for your work and workspace.

Welding And Cutting Fumes
Grinding Dust
Metal Chips
Facility Cleaning
Applications
- FumesExtraction from welding and cutting processes.
- DustGrinding and surface treatment dust.
- ChipsExtraction of heavy metalworking chips.
- Grit and granulateTransfer of industrial waste and raw materials.
Three Details To Help Us Choose
We consider the extraction points and the material to be collected when selecting a high-vacuum system.
- Dust, chips or other material to collect
- Hose lengths and number of extraction points
- Simultaneous use and waste discharge arrangements
Frequently Asked Questions
How Does The FlexPAK Adjust Extraction Power?
An electronic vacuum controller adjusts motor speed to demand. Filters are cleaned automatically by reverse-air pulses configured through the PLC.
Are The Standard FlexPAK And DX The Same Configuration?
DX versions have separate protection arrangements for combustible-dust applications. The general specification table on this page covers the standard series; motor, supply and DX configuration are confirmed separately with the quotation.
What Information Helps With Model Selection?
We consider the extraction points and the material to be collected when selecting a high-vacuum system. For an assessment, please share: dust, chips or other material to collect; hose lengths and number of extraction points; simultaneous use and waste discharge arrangements.
How Can I Get Maintenance And Spare-Parts Support?
Share the equipment model, serial number if available and your requirements with our service team. We can assess maintenance or replacement needs for the filter or part fitted.
How Can I Get Pricing And Delivery Information?
“Request a quotation” adds the selected model to the contact form. Describe your application and equipment needs; configuration, pricing and delivery details are provided with the quotation.
Support Beyond Installation.
Talk to the same team about site surveys, installation, maintenance and spare parts. For existing equipment, share the model and serial number.
| Specification | Value |
|---|---|
| Maximum airflow | 1300 m³/h |
| Airflow at -15 kPa | 1000 m³/h |
| Airflow at -20 kPa | 800 m³/h |
| Maximum vacuum | -35 kPa |
| Filter area | 6 m² |
| Motor power / supply | 18.5 kW / 400 V; 21.5 kW / 460 V |
| Inlet / outlet diameter | 150 / 160 mm |
| Noise level | 70 dB(A) |
| Compressed-air pressure | 6–10 bar |
| Extracted air temperature | 0–60 °C |
Models & Options
Model, electrical supply and accessories should be considered together.
Product Codes (SKU)
- FlexPAK 80040050160
- FlexPAK 800DX40050312
- FlexPAK 100040050260
- FlexPAK 1000DX40050322
Request a Quote for This Product